• LMZB-24 Outdoor Current Transformer
LMZB-24 Outdoor Current Transformer
discuss personally
Model
LMZB-24
Basic info
Brand Wone Store
Model NO. LMZB-24 Outdoor Current Transformer
Rated voltage 22kV
Rated frequency 50/60Hz
Rated current ratio 500/5
Series LMZB
Product Detail

Product Overview

LMZB-24 epoxy resin casting busbar type current transformer, is widely used outdoor for measuring current, electric energy and protective relaying in the electrical system with rated frequency 50Hz or 60Hz and highest voltage for equipment 24kV.  Rated primary current is 400-10000Aand rated secondary current is 5A or 1A.

Key Features

  • 24kV-Class Outdoor High-Voltage Adaptation Design:The LMZB1-24 outdoor current transformer features a 24kV rated voltage design with insulation levels reaching 75kV (lightning impulse) / 40kV (power frequency withstand voltage). It strictly complies with GB/T 4703.2 and IEC 60044-2 standards, and is optimized specifically for scenarios such as 20kV and below outdoor substations, ring main units, and cable distribution boxes. Its structural design fully accounts for the long-term operational requirements of high-voltage outdoor environments, effectively resisting voltage fluctuations and insulation aging, reducing the risk of equipment failures caused by insulation breakdown, and ensuring the stable operation of the power system.

  •  All-Climate Protection Structure:This product adopts a dual protective barrier composed of silicone rubber composite insulation material and a corrosion-resistant aluminum alloy shell: it has passed 7000 hours of UV aging testing, enabling it to withstand long-term outdoor exposure; it reaches IP68 protection level, allowing continuous operation at 1 meter underwater. Meanwhile, through a specially designed structure, it can resist snowfall of 20mm/h and ice loads of 10mm thickness. Verified by 2000 hours of salt spray testing, it has a creepage distance of 20mm/kV, making it suitable for various harsh outdoor environments such as coastal areas, high-altitude regions, and cold areas, and reducing the impact of climatic factors on equipment performance.

  • Dual-Winding High-Precision Measurement System:It integrates a 0.2S-class metering winding and a 5P20-class protection winding. The metering winding maintains a ratio error of ≤±0.2% within the range of 1%~120% rated current, meeting the requirements of high-precision electric energy metering and line loss analysis; the protection winding has a composite error of ≤5% under 20 times the rated current, with a response time of ≤10ms, which can quickly trigger relay protection devices to ensure safe disconnection in case of power grid faults. It is equipped with 2 sets of ratio taps (such as 300/5A, 600/5A), which can be adjusted through an outdoor sealed changeover switch, adapting to different load currents without disassembly, thus improving the flexibility of on-site application.

  • Enhanced Safety and Environmental Adaptability:It is built with a pressure balance valve to avoid shell condensation and air pressure deformation caused by temperature differences, and can be optionally equipped with explosion-proof certification (Ex d IIB T4), making it suitable for outdoor areas with flammable and explosive risks. Its anti-electromagnetic interference performance complies with IEC 61000-4-5 standards, and it can resist 60kA lightning strikes (10/350μs waveform). It maintains stable measurement accuracy even in strong electromagnetic environments, providing reliable current monitoring and protection guarantees for 20kV-class outdoor power grids.

Main technical parameter

  • Rated voltage: 20 kV or 22kV etc

  • Rated secondary current:5Aor1A

  • Rated insulation level: 24/50/125 kV

  • Standards: IEC60044-1.2003 Part 1: Instrument transformers-Part1: Current transformers or IEC61869-1&2-2012 etc.

Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.

Outline

Know your supplier
Wone Store
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/Instrument Transformer/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
A hybrid DC circuit breaker
A hybrid DC circuit breaker
Most DC molded-case circuit breakers use natural air arc extinction, and there are typically two arc extinguishing methods: one is conventional opening and closing, where the contacts axially stretch the arc, while the conductive circuit generates a magnetic field that bends and elongates the arc, pulling it lengthwise perpendicular to the arc axis. This not only increases the arc length but also induces lateral motion, enabling air cooling to achieve arc extinction.The other method involves the
Echo
09/02/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!